AC Load Banks
Analog & Digital AC Load Testing
Eagle Eye Power Solutions offers multiple load banks for any generator load test requirement. The LB-Series AC has multiple different series of load banks each designed for a different application including digital and analog models. The purpose of the AC load bank tester is to accurately mimic the operational load a power source will encounter in an actual application. Eagle Eye load banks perform tests for a wide variety of applications including generator load testing. Eagle Eye also offers DC Load Banks for DC applications.
Eagle Eye has numerous standard models for each series and application. Custom solutions are available - please let us know your requirements and Request a Quote today.
-
Digital AC Resistive Single Phase Load Banks
Model # LB-AC-Digital-Single-Phase
LB-Series Digital AC Single Phase Load Banks are designed for testing single phase sources including generators, UPS, and other critical AC power systems. Standard models range from 10 – 200 kW to cover a wide variety of testing applications. Voltages include 120, 240 or 120/240 VAC. Controls feature local mode with digital display and intelligent remote control software with manual or automatic load profile operation. 1 kW resolution is included or precise load control.
More Info Request a Quote -
Digital AC Portable Resistive Three-Phase Load Banks
Model # LB-AC-Digital-Three-Phase
LB-Series Digital AC Portable Resistive Three Phase Load Banks are designed for unity power factor testing of generators, UPS, and other critical AC power sources. Available from 10 – 1,000 kW in a portable platform. Voltages include 208, 240, 480 and 600 VAC. Included 1 kW resolution insures precise load control. Local manual control with digital display and intelligent remote control software provides automatic load profiles plus recording and display of all load test data.
More Info Request a Quote -
Digital Outdoor Resistive Load Banks
Model # LB-AC-Digital-Outdoor-Resistive
LB-Series Digital Outdoor Resistive Load Banks are designed for testing AC power system like generator, OEM, UPS or other sources. Available from 10 kW - 6,000 kW. Enclosures feature steel construction for durability. Voltages include 208, 240, 480 or 600 VAC with others available. Controls include local manual mode with digital display plus intelligent remote control software for automatic load profiles with display and recording all load test data. 1 kW load step resolution allows precise load control during system testing.
More Info Request a Quote -
Analog AC Compact Portable Load Banks
Model # AC-LB-Series-Analog
Portable AC Analog Load Banks are compact, lightweight and easy to handle and set up. Designed for testing many 60 & 400 Hz power systems including gen set, UPS, aircraft GPU's and other AC power systems. Each load bank is fully self-contained and designed for portable AC load testing. Our resistor design and assembly make it possible to achieve smaller portable load banks than any one in the industry.
More Info Request a Quote -
Digital AC Reactive Load Banks
Model # LBR/LBC-AC-Digital-Reactive
LBR-Series Digital AC Reactive Load Banks are designed for reactive load testing of AC power systems including diesel gen sets, UPS, and other critical AC power sources. For full kVA testing resistive and reactive load banks operate in parallel for power factors including 0.8 for gen set work. Available in Inductive or Capacitive versions for lagging or leading power factor testing. Models range from 37.5 kVAR - 2,500 kVAR(C). Voltage include 208, 240,480 or 600 VAC with others available.
More Info Request a Quote -
Digital AC Resistive Reactive Load Banks
Model # RLB-AC-Digital-Resistive/Reactive
RLB-Series Digital AC Resistive Reactive Load Banks are designed for full kVA load testing many AC power systems like diesel gen sets, OEM’s, UPS, and other critical AC power sources. They combine resistive and reactive loads into one enclosure and provide a single point load connection. Resistive and Inductive or Capacitive versions are available for lagging or leading power factor testing from 37.5 kVA - 2,500 kVA with voltages including 208, 240, 480 or 600 VAC three phase with others available.
More Info Request a Quote -
AC Rack Mount Server Load Banks
Model # LB-AC-Digital
The LB-Series AC Rack Mount Server Load Banks are designed for data center testing of power and heat loading applications. Standard 7U or 9U size configurations are available. Standard voltages include 120, 208 or 240 VAC. Load configurations include 4-20 kW with others available. Controls feature simple load control with resolution of 1 kW. Safety features include over-temp protection and visual normal / fault condition indication and audible alarm.
More Info Request a Quote